The accuracy of the mounting surface depends on the required accuracy of the machine itself. Too much mounting error, however, causes the slide unit to warp, and shortens its life. Table below shows the general standard of allowable tolerances of mounting accuracy.

Model No.

Parallelism between two axes
‚…1F‚Q޲‚Ì•½s“xŒë·iƒÊmj

Height error of two axes
‚…2F‚Q޲‚Ì‚‚³Œë·immj

LMBM5

2

0.020/200L

LMBM7,LMBM7W

3

0.025/200L

LMBM9,LMBM9W

4

0.035/200L

LMBM12,LMBM12W

9

0.050/200L

LMBM15,LMBM15W

10

0.060/200L

LMBM20

13

0.110/200L

HS15 ,HC15L

13

0.330/500L

HC15

16

HC20L,HS20

17

HC20

20

HS25 ,HC25L

21

HS25L

20

HC25

24

HS30 ,HC30L

25

HS30L

24

HC30

29

HS35 ,HC35L

29

HS35L

27

HC35

33

HS45 ,HC45L

38

HS45L

36

HS55 ,HC55L

46

HS55L

44

HS65

59

HS65L

55